copy of Housing 1-cartridge filter system
Reversible air-cooled heat pump with scroll compressors 12.8 - 88.4 kW
Nominal cooling capacity 456 - 1934 kW. Nominal heat output 399 - 1721 kW.
The water-cooled units with screw compressor represent the best solution for commercial or industrial applications where reliability and high performance are required. The units have been designed to best meet the market demands in terms of versatility and energy efficiency, using top brand components. The stepless regulation of the cooling capacity, the use of electronic expansion valves and heat exchangers with integrated recovery systems, help to maximize energy efficiency at full load and at partial loads, achieving exceptional seasonal performance. These machines respond optimally to the complex requirements of use in the cooling of industrial processes.
Low GWP R513A refrigerant;
Seasonal energy efficiency compliant with the requirements of Directive 2009/125 / EC ErP;
High energy efficiency, especially at partial loads;
Continuous “smart stepless” regulation of the cooling capacity with self-adaptive control of the partitioning speed;
Command logic that guarantees a high degree of precision in controlling the throttling of the compressors;
Single compressor partialization up to 25% of the cooling capacity;
Heat exchangers with low water pressure drops to contain the operating costs of the pumping groups;
Integrated systems for partial or total heat recovery;
Condenser water outlet temperature up to 60 ° C.
Cooling capacity kW (1); Nominal operating conditions: evaporator IN / OUT water temperature + 12 / + 7 ° C; condenser IN / OUT water temperature + 30 / + 35 ° C (UNI EN 14511: 2018).
Cooling capacity kW (2); Nominal operating conditions: evaporator IN / OUT water temperature + 20 / + 15 ° C; condenser IN / OUT water temperature + 30 / + 35 ° C (UNI EN 14511: 2018).
Thermal power kW; Nominal operating conditions (HP version): condenser IN / OUT water temperature + 40 / + 45 ° C; evaporator IN / OUT water temperature + 12 / + 7 ° C (UNI EN 14511: 2018).
Insulated condensers and delivery pipes; Version with cycle inversion on the hydraulic side and condenser outlet water temperature up to 60 ° C; compared to the CH version, the condensers and the delivery pipes are thermally insulated to avoid heat dispersion, furthermore the units are equipped with temperature probes for thermostating condenser side in heating mode; the positioning of the probes and the reversing valves on the hydraulic side are the responsibility of the customer.
Version suitable for evaporator water temperatures down to -8 ° C. The use of anti-freeze additives in adequate concentration is recommended.
This type of article can be 100% customized to your needs;
We produce custom-designed equipment request a free quote - CONTACT US -
Standard features
High efficiency screw compressors with continuous regulation of the cooling capacity and optimized for R513A refrigerant gas;
Non-return valve and shut-off valve on compressor delivery;
Heating resistance of the compressor crankcase and phase monitor;
Automatic switches on the compressor power circuit;
Electronic expansion valves;
Single-pass shell and tube heat exchangers optimized for R513A refrigerant gas;
"Unloading" function that allows the start-up of the system and the operation of the machine, even in conditions very different from the nominal ones;
Programmable electronic controller with microprocessor with high calculation capacity and easy-to-use graphic interface, designed for connectivity to supervision systems with RS485 Modbus protocol;
Degree of protection of the electrical panel: IP54;
Testing and tests carried out in the factory on all models;
Filling of anti-freeze oil and refrigerant carried out in the factory.
Options
Soundproofing panels for compressors;
Water side reversible heat pump configuration;
MWT configuration for low evaporator water outlet temperatures (down to -8 ° C);
Partial heat recovery - desuperheater (20% heat recovery);
Total heat recovery (100% heat recovery);
Compressor suction shut-off cock;
Soft-start starters for compressors;
Power factor correction capacitors (cosф> 0.9).
Kits sold separately
Pressostatic or modulating valves for condensation control;
Flanged type hydraulic connections (evaporator side);
Victaulic or flanged hydraulic connections (condenser and recovery side);
Antivibration supports;
Remote display;
xWEB300D EVO for monitoring, control and archiving of data, based on "WEB server" technology;
Modularity kit, for master / slave network management up to 7 units.
Customers who bought this product also bought:
14 other products in the same category:
Semi-automatic capsule processing machine hourly output 16,000
Pioneer® PX Analytical Balance
Aphrometer for full bottles aluminium crown cap diameter 26 and 29 mm
Laboratory instrument for pH measurement with integrated printer
Air cooled liquid chiller - Super low noise acoustic configuration 232 - 1334 kW
Air-cooled liquid chillers - Basic acoustic configuration 382 ÷ 1945 kW
Acid and corrosive electric pump 90 litres / minute
Single screw pump with floating stator 10 - 2000 rpm 7 minute 2 - 42 hectolitres / hour -...
Optech Stereomicroscopes GZ 808 series
NITROGEN GENERATOR STORM SERIES 1 m³ / hour
Automatic dosing and capping monobloc for cosmetics and food products 800 bottles 7 hours
CE (European Community) ADDITIONAL Kit Manometer mounted on remote table stand